The following references are intended for licensed endodontists and general practitioners with advanced endodontic training. All settings and sequences are starting points; adjust to canal anatomy, patient presentation, and your motor’s torque characteristics.

Motor Settings

Rotary Shaping — Pro Series Solo — Gold

Instrument Speed (RPM) Torque (N·cm) Motion
[S1 equivalent] [TBD] [TBD] Continuous rotation
[S2 equivalent] [TBD] [TBD] Continuous rotation
[F1 equivalent] [TBD] [TBD] Continuous rotation

Reciprocating — Pro Series Solo — Gold & Glide — Gold

Instrument CW Angle CCW Angle Speed
Pro Series Solo — Gold [TBD]° [TBD]° [TBD] RPM
Pro Series Glide — Gold [TBD]° [TBD]° [TBD] RPM

Glide Path — Pro Series Glide (Silver)

Instrument Speed (RPM) Torque (N·cm) Motion
Pro Series Glide (Silver) [TBD] [TBD] Continuous rotation

Retreatment — Pro Series Retreatment

Instrument Speed (RPM) Torque (N·cm) Third
D1 [TBD] [TBD] Coronal
D2 [TBD] [TBD] Middle
D3 [TBD] [TBD] Apical

Suggested Sequences

Straight Canal — Rotary Protocol

  1. Establish straight-line access and confirm patency with a size 10 hand file.
  2. Pro Series C-Plus size 10 to working length.
  3. Pro Series Glide (Silver) to working length.
  4. Pro Series Solo — Gold [S1 position] to working length using a gentle in-and-out pecking motion, 3–4 mm amplitude.
  5. Pro Series Solo — Gold [S2 position] to working length.
  6. Pro Series Solo — Gold [F1 position] to working length. Confirm apical size with a hand file.
  7. Irrigate, dry, and obturate per your preferred technique.

Curved Canal — Reciprocating Protocol

  1. Establish patency with Pro Series C-Plus size 10, pre-curved.
  2. Pro Series Glide — Gold to working length in reciprocating motion.
  3. Pro Series Solo — Gold (reciprocating setting) to working length. Use a light apical pressure; allow the instrument to advance passively.
  4. Confirm apical size. Irrigate and obturate.

Sterilization & Infection Control

Pro Series instruments are single-use. Do not resterilize or reuse. Discard after each case.

  • Inspect each instrument under magnification before use. Do not use instruments showing unwinding, deformation, or surface defects.
  • Store in original packaging until point of use.
  • Dispose of used instruments per your facility’s sharps protocol.

Instrument Inspection Criteria

  • Unwinding of flutes: discard immediately.
  • Visible torsional deformation: discard immediately.
  • Any instrument used in a calcified or previously instrumented canal: discard after the case regardless of visual appearance.

All [TBD] fields are placeholders. Replace with verified motor settings from the current product spec sheet before publishing. Do not publish until all clinical data has been confirmed.